Copper · Reference · isotropic

Annealed copper, IACS reference

International Annealed Copper Standard · annealed, 20 °C

Annealed copper, IACS reference is a reference value to International Annealed Copper Standard.

Record
cu-iacs
Library
v1.1.0
Properties
4
Sources
1
Build check
passed ✓
Viewing as
guest
+ Compare Cite Download · PRO
ρ · Density 8890kg/m³ definition[1]
σ_e · Electrical conductivity 58MS/m definition[1]

Physical, thermal and electrical

at 20 °C
SymbolPropertyValueUnitBasisRef.
σ_e Electrical conductivity ⓘ 100 % IACS at 20 °C 58 MS/m definition [1]
ρ_e Electrical resistivity ⓘ 1.7241 µΩ·cm at 20 °C 0.01724 µΩ·m definition [1]
IACS Conductivity relative to annealed copper 100 % definition [1]
ρ Density ⓘ the density the standard assumes 8890 kg/m³ definition [1]

Notes

  • The reference against which conductors are graded; not a purchasable product.

Sources

every value names one
  1. NBS Handbook 100, Copper wire tables (1966) — the International Annealed Copper StandardCopies checked: 1

min product standard minimum char characteristic design code value for design typical datasheet or textbook derived worked out here, formula shown

Cite this page

for reports and papers

BadgerMecX Materials (2026). Annealed copper, IACS reference — material properties, International Annealed Copper Standard. Library v1.1.0, record cu-iacs. https://badgermecx.com/materials/cu-iacs/ (accessed 2026-10-08).

@misc{badgermecx_cuiacs,
  title  = {Annealed copper, IACS reference -- material properties, International Annealed Copper Standard},
  author = {{BadgerMecX Materials}},
  year   = {2026},
  note   = {Library v1.1.0, record cu-iacs},
  url    = {https://badgermecx.com/materials/cu-iacs/}
}

Export and related