C24 vs C50

C50 is 1.5 times as stiff as C24. It is 1.2 times as dense. Per unit mass C50 is 1.2 times as stiff. Strength: f_m,k = 24 MPa for C24, f_m,k = 50 MPa for C50.

Side by side

ratio = C50 / C24 · log scale
Property C24 C50UnitRatio¼×1×4×
E₁ Modulus, direction 1 11 16 GPa 1.45×
E₂ Modulus, direction 2 0.37 0.53 GPa 1.43×
E₃ Modulus, direction 3 0.37 0.53 GPa 1.43×
G₁₂ Shear modulus 1-2 0.69 1 GPa 1.45×
G₁₃ Shear modulus 1-3 0.69 1 GPa 1.45×
E₀,₀₅ Modulus parallel to grain, 5 % fractile 7.4 10.7 GPa 1.45×
ρ Density 420 520 kg/m³ 1.24×
ρ_k Density, characteristic (5 % fractile) 350 430 kg/m³ 1.23×
f_m,k Bending strength 24 50 MPa 2.08×
f_t,0,k Tension parallel to grain 14.5 33.5 MPa 2.31×
f_t,90,k Tension perpendicular to grain 0.4 0.4 MPa 1×
f_c,0,k Compression parallel to grain 21 30 MPa 1.43×
f_c,90,k Compression perpendicular to grain 2.5 3 MPa 1.2×
f_v,k Shear strength 4 4 MPa 1×
E/ρ Specific stiffness E/ρ · derived 26.19 30.77 MJ/kg 1.17×
c₀ Bar wave speed √(E/ρ) · derived 5118 5547 m/s 1.08×
f/ρ Specific strength f/ρ · derived 57.14 96.15 kJ/kg 1.68×

Values at the first thickness band or product form of each material (EN 338:2016; EN 338:2016). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.