C20 vs C24

C24 is 1.2 times as stiff as C20. Their densities are about the same. Per unit mass C24 is 1.1 times as stiff. Strength: f_m,k = 20 MPa for C20, f_m,k = 24 MPa for C24.

Side by side

ratio = C24 / C20 · log scale
Property C20 C24UnitRatio¼×1×4×
E₁ Modulus, direction 1 9.5 11 GPa 1.16×
E₂ Modulus, direction 2 0.32 0.37 GPa 1.16×
E₃ Modulus, direction 3 0.32 0.37 GPa 1.16×
G₁₂ Shear modulus 1-2 0.59 0.69 GPa 1.17×
G₁₃ Shear modulus 1-3 0.59 0.69 GPa 1.17×
E₀,₀₅ Modulus parallel to grain, 5 % fractile 6.4 7.4 GPa 1.16×
ρ Density 400 420 kg/m³ 1.05×
ρ_k Density, characteristic (5 % fractile) 330 350 kg/m³ 1.06×
f_m,k Bending strength 20 24 MPa 1.2×
f_t,0,k Tension parallel to grain 11.5 14.5 MPa 1.26×
f_t,90,k Tension perpendicular to grain 0.4 0.4 MPa 1×
f_c,0,k Compression parallel to grain 19 21 MPa 1.11×
f_c,90,k Compression perpendicular to grain 2.3 2.5 MPa 1.09×
f_v,k Shear strength 3.6 4 MPa 1.11×
E/ρ Specific stiffness E/ρ · derived 23.75 26.19 MJ/kg 1.1×
c₀ Bar wave speed √(E/ρ) · derived 4873 5118 m/s 1.05×
f/ρ Specific strength f/ρ · derived 50 57.14 kJ/kg 1.14×

Values at the first thickness band or product form of each material (EN 338:2016; EN 338:2016). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.