C14 vs C20
C20 is 1.4 times as stiff as C14. It is 1.1 times as dense. Per unit mass C20 is 1.2 times as stiff. Strength: f_m,k = 14 MPa for C14, f_m,k = 20 MPa for C20.
Side by side
ratio = C20 / C14 · log scale| Property | C14 | C20 | Unit | Ratio | ¼×1×4× |
|---|---|---|---|---|---|
| E₁ Modulus, direction 1 | 7 | 9.5 | GPa | 1.36× | |
| E₂ Modulus, direction 2 | 0.23 | 0.32 | GPa | 1.39× | |
| E₃ Modulus, direction 3 | 0.23 | 0.32 | GPa | 1.39× | |
| G₁₂ Shear modulus 1-2 | 0.44 | 0.59 | GPa | 1.34× | |
| G₁₃ Shear modulus 1-3 | 0.44 | 0.59 | GPa | 1.34× | |
| E₀,₀₅ Modulus parallel to grain, 5 % fractile | 4.7 | 6.4 | GPa | 1.36× | |
| ρ Density | 350 | 400 | kg/m³ | 1.14× | |
| ρ_k Density, characteristic (5 % fractile) | 290 | 330 | kg/m³ | 1.14× | |
| f_m,k Bending strength | 14 | 20 | MPa | 1.43× | |
| f_t,0,k Tension parallel to grain | 7.2 | 11.5 | MPa | 1.6× | |
| f_t,90,k Tension perpendicular to grain | 0.4 | 0.4 | MPa | 1× | |
| f_c,0,k Compression parallel to grain | 16 | 19 | MPa | 1.19× | |
| f_c,90,k Compression perpendicular to grain | 2 | 2.3 | MPa | 1.15× | |
| f_v,k Shear strength | 3 | 3.6 | MPa | 1.2× | |
| E/ρ Specific stiffness E/ρ · derived | 20 | 23.75 | MJ/kg | 1.19× | |
| c₀ Bar wave speed √(E/ρ) · derived | 4472 | 4873 | m/s | 1.09× | |
| f/ρ Specific strength f/ρ · derived | 40 | 50 | kJ/kg | 1.25× |
Values at the first thickness band or product form of each material (EN 338:2016; EN 338:2016). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.