C14 vs C30

C30 is 1.7 times as stiff as C14. It is 1.3 times as dense. Per unit mass C30 is 1.3 times as stiff. Strength: f_m,k = 14 MPa for C14, f_m,k = 30 MPa for C30.

Side by side

ratio = C30 / C14 · log scale
Property C14 C30UnitRatio¼×1×4×
E₁ Modulus, direction 1 7 12 GPa 1.71×
E₂ Modulus, direction 2 0.23 0.4 GPa 1.74×
E₃ Modulus, direction 3 0.23 0.4 GPa 1.74×
G₁₂ Shear modulus 1-2 0.44 0.75 GPa 1.7×
G₁₃ Shear modulus 1-3 0.44 0.75 GPa 1.7×
E₀,₀₅ Modulus parallel to grain, 5 % fractile 4.7 8 GPa 1.7×
ρ Density 350 460 kg/m³ 1.31×
ρ_k Density, characteristic (5 % fractile) 290 380 kg/m³ 1.31×
f_m,k Bending strength 14 30 MPa 2.14×
f_t,0,k Tension parallel to grain 7.2 19 MPa 2.64×
f_t,90,k Tension perpendicular to grain 0.4 0.4 MPa 1×
f_c,0,k Compression parallel to grain 16 24 MPa 1.5×
f_c,90,k Compression perpendicular to grain 2 2.7 MPa 1.35×
f_v,k Shear strength 3 4 MPa 1.33×
E/ρ Specific stiffness E/ρ · derived 20 26.09 MJ/kg 1.3×
c₀ Bar wave speed √(E/ρ) · derived 4472 5108 m/s 1.14×
f/ρ Specific strength f/ρ · derived 40 65.22 kJ/kg 1.63×

Values at the first thickness band or product form of each material (EN 338:2016; EN 338:2016). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.