C14 vs C24

C24 is 1.6 times as stiff as C14. It is 1.2 times as dense. Per unit mass C24 is 1.3 times as stiff. Strength: f_m,k = 14 MPa for C14, f_m,k = 24 MPa for C24.

Side by side

ratio = C24 / C14 · log scale
Property C14 C24UnitRatio¼×1×4×
E₁ Modulus, direction 1 7 11 GPa 1.57×
E₂ Modulus, direction 2 0.23 0.37 GPa 1.61×
E₃ Modulus, direction 3 0.23 0.37 GPa 1.61×
G₁₂ Shear modulus 1-2 0.44 0.69 GPa 1.57×
G₁₃ Shear modulus 1-3 0.44 0.69 GPa 1.57×
E₀,₀₅ Modulus parallel to grain, 5 % fractile 4.7 7.4 GPa 1.57×
ρ Density 350 420 kg/m³ 1.2×
ρ_k Density, characteristic (5 % fractile) 290 350 kg/m³ 1.21×
f_m,k Bending strength 14 24 MPa 1.71×
f_t,0,k Tension parallel to grain 7.2 14.5 MPa 2.01×
f_t,90,k Tension perpendicular to grain 0.4 0.4 MPa 1×
f_c,0,k Compression parallel to grain 16 21 MPa 1.31×
f_c,90,k Compression perpendicular to grain 2 2.5 MPa 1.25×
f_v,k Shear strength 3 4 MPa 1.33×
E/ρ Specific stiffness E/ρ · derived 20 26.19 MJ/kg 1.31×
c₀ Bar wave speed √(E/ρ) · derived 4472 5118 m/s 1.14×
f/ρ Specific strength f/ρ · derived 40 57.14 kJ/kg 1.43×

Values at the first thickness band or product form of each material (EN 338:2016; EN 338:2016). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.