D45 vs D75

D75 is 1.6 times as stiff as D45. It is 1.5 times as dense. Per unit mass D75 is 1.1 times as stiff. Strength: f_m,k = 45 MPa for D45, f_m,k = 75 MPa for D75.

Side by side

ratio = D75 / D45 · log scale
Property D45 D75UnitRatio¼×1×4×
E₁ Modulus, direction 1 13.5 22 GPa 1.63×
E₂ Modulus, direction 2 0.9 1.47 GPa 1.63×
E₃ Modulus, direction 3 0.9 1.47 GPa 1.63×
G₁₂ Shear modulus 1-2 0.84 1.38 GPa 1.64×
G₁₃ Shear modulus 1-3 0.84 1.38 GPa 1.64×
E₀,₀₅ Modulus parallel to grain, 5 % fractile 11.3 18.5 GPa 1.64×
ρ Density 700 1020 kg/m³ 1.46×
ρ_k Density, characteristic (5 % fractile) 580 850 kg/m³ 1.47×
f_m,k Bending strength 45 75 MPa 1.67×
f_t,0,k Tension parallel to grain 27 45 MPa 1.67×
f_t,90,k Tension perpendicular to grain 0.6 0.6 MPa 1×
f_c,0,k Compression parallel to grain 29 37 MPa 1.28×
f_c,90,k Compression perpendicular to grain 5.8 12.8 MPa 2.21×
f_v,k Shear strength 4.4 5 MPa 1.14×
E/ρ Specific stiffness E/ρ · derived 19.29 21.57 MJ/kg 1.12×
c₀ Bar wave speed √(E/ρ) · derived 4392 4644 m/s 1.06×
f/ρ Specific strength f/ρ · derived 64.29 73.53 kJ/kg 1.14×

Values at the first thickness band or product form of each material (EN 338:2016; EN 338:2016). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.