D30 vs D45

D45 is 1.2 times as stiff as D30. It is 1.1 times as dense. Per unit mass D45 is 1.1 times as stiff. Strength: f_m,k = 30 MPa for D30, f_m,k = 45 MPa for D45.

Side by side

ratio = D45 / D30 · log scale
Property D30 D45UnitRatio¼×1×4×
E₁ Modulus, direction 1 11 13.5 GPa 1.23×
E₂ Modulus, direction 2 0.73 0.9 GPa 1.23×
E₃ Modulus, direction 3 0.73 0.9 GPa 1.23×
G₁₂ Shear modulus 1-2 0.69 0.84 GPa 1.22×
G₁₃ Shear modulus 1-3 0.69 0.84 GPa 1.22×
E₀,₀₅ Modulus parallel to grain, 5 % fractile 9.2 11.3 GPa 1.23×
ρ Density 640 700 kg/m³ 1.09×
ρ_k Density, characteristic (5 % fractile) 530 580 kg/m³ 1.09×
f_m,k Bending strength 30 45 MPa 1.5×
f_t,0,k Tension parallel to grain 18 27 MPa 1.5×
f_t,90,k Tension perpendicular to grain 0.6 0.6 MPa 1×
f_c,0,k Compression parallel to grain 24 29 MPa 1.21×
f_c,90,k Compression perpendicular to grain 5.3 5.8 MPa 1.09×
f_v,k Shear strength 3.9 4.4 MPa 1.13×
E/ρ Specific stiffness E/ρ · derived 17.19 19.29 MJ/kg 1.12×
c₀ Bar wave speed √(E/ρ) · derived 4146 4392 m/s 1.06×
f/ρ Specific strength f/ρ · derived 46.88 64.29 kJ/kg 1.37×

Values at the first thickness band or product form of each material (EN 338:2016; EN 338:2016). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.