C45/55 vs C50/60

C50/60 and C45/55 are about equally stiff. Their densities are about the same. Per unit mass they are about equally stiff (14.71 and 15.12 MJ/kg). Strength: f_ck = 45 MPa for C45/55, f_ck = 50 MPa for C50/60.

Side by side

ratio = C50/60 / C45/55 · log scale
Property C45/55 C50/60UnitRatio¼×1×4×
E Young's modulus 36 37 GPa 1.03×
G Shear modulus 15 15.42 GPa 1.03×
ν Poisson's ratio 0.2 0.2 – 1×
ρ Density 2447 2447 kg/m³ 1×
γ Weight density 24 24 kN/m³ 1×
α Coefficient of thermal expansion 10 10 10⁻⁶/K 1×
f_ck Characteristic cylinder strength 45 50 MPa 1.11×
f_ck,cube Characteristic cube strength 55 60 MPa 1.09×
f_cm Mean cylinder strength 53 58 MPa 1.09×
f_ctm Mean tensile strength 3.8 4.1 MPa 1.08×
f_ctk,0.05 Tensile strength, 5 % fractile 2.7 2.9 MPa 1.07×
f_ctk,0.95 Tensile strength, 95 % fractile 4.9 5.3 MPa 1.08×
ε_c1 Strain at peak stress 2.4 2.45 ‰ 1.02×
ε_cu1 Ultimate strain 3.5 3.5 ‰ 1×
ε_c2 Strain at peak, parabola–rectangle 2 2 ‰ 1×
ε_cu2 Ultimate strain, parabola–rectangle 3.5 3.5 ‰ 1×
n Exponent, parabola–rectangle 2 2 – 1×
ε_c3 Strain at peak, bilinear 1.75 1.75 ‰ 1×
ε_cu3 Ultimate strain, bilinear 3.5 3.5 ‰ 1×
E/ρ Specific stiffness E/ρ · derived 14.71 15.12 MJ/kg 1.03×
c₀ Bar wave speed √(E/ρ) · derived 3835 3888 m/s 1.01×
f/ρ Specific strength f/ρ · derived 18.39 20.43 kJ/kg 1.11×

Values at the first thickness band or product form of each material (EN 1992-1-1; EN 1992-1-1). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.