C35/45 vs C45/55

C45/55 and C35/45 are about equally stiff. Their densities are about the same. Per unit mass they are about equally stiff (13.89 and 14.71 MJ/kg). Strength: f_ck = 35 MPa for C35/45, f_ck = 45 MPa for C45/55.

Side by side

ratio = C45/55 / C35/45 · log scale
Property C35/45 C45/55UnitRatio¼×1×4×
E Young's modulus 34 36 GPa 1.06×
G Shear modulus 14.17 15 GPa 1.06×
ν Poisson's ratio 0.2 0.2 – 1×
ρ Density 2447 2447 kg/m³ 1×
γ Weight density 24 24 kN/m³ 1×
α Coefficient of thermal expansion 10 10 10⁻⁶/K 1×
f_ck Characteristic cylinder strength 35 45 MPa 1.29×
f_ck,cube Characteristic cube strength 45 55 MPa 1.22×
f_cm Mean cylinder strength 43 53 MPa 1.23×
f_ctm Mean tensile strength 3.2 3.8 MPa 1.19×
f_ctk,0.05 Tensile strength, 5 % fractile 2.2 2.7 MPa 1.23×
f_ctk,0.95 Tensile strength, 95 % fractile 4.2 4.9 MPa 1.17×
ε_c1 Strain at peak stress 2.25 2.4 ‰ 1.07×
ε_cu1 Ultimate strain 3.5 3.5 ‰ 1×
ε_c2 Strain at peak, parabola–rectangle 2 2 ‰ 1×
ε_cu2 Ultimate strain, parabola–rectangle 3.5 3.5 ‰ 1×
n Exponent, parabola–rectangle 2 2 – 1×
ε_c3 Strain at peak, bilinear 1.75 1.75 ‰ 1×
ε_cu3 Ultimate strain, bilinear 3.5 3.5 ‰ 1×
E/ρ Specific stiffness E/ρ · derived 13.89 14.71 MJ/kg 1.06×
c₀ Bar wave speed √(E/ρ) · derived 3727 3835 m/s 1.03×
f/ρ Specific strength f/ρ · derived 14.3 18.39 kJ/kg 1.29×

Values at the first thickness band or product form of each material (EN 1992-1-1; EN 1992-1-1). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.