TOOL C-29 · v1.0.0 · FREE · NO SIGN-UP

C-29 · THERMAL & FLUID · HEAT EXCHANGERS

Heat exchangers

Rate or size a double-pipe, shell-and-tube or gasketed plate exchanger: duty, outlet temperatures, film coefficients, area and pressure drops — with the streams running through it, coloured by temperature.

FREE · NO SIGN-UP v1.0.0 · verified against 13 reference cases
INPUT°C · kg/s · mm
1 · Hot stream

2 · Cold stream

3 · Hairpins

Example values. Fluid properties from the VDI Heat Atlas tables, or enter your own fluid.

DUTY273.4 kW
OVERALL U846 W/m²K
AREA5.12 m²
OUTLETS92.6 · 85.4 °C
FLOW · LIVE

TEMPERATURE ALONG THE EXCHANGER
  • Water at 140 °C stays liquid only above 3.62 bar(a) — keep the system pressure above that.
Free with an account · Sign in

HOW IT'S CALCULATED · WITH YOUR NUMBERS

Step by step, with your numbers

References: VDI Heat Atlas 2nd ed. (2010) — G1, G2 (Gnielinski), N6 (Martin) and the fluid tables of D2 and D4; Serth & Lestina, Process Heat Transfer 2nd ed. (2014), ch. 4–6 (hairpins, Delaware method); Shah & Sekulić, Fundamentals of Heat Exchanger Design, ch. 3 (ε-NTU, F); Kakaç et al., Heat Exchangers 3rd ed. (2012), ch. 7, 9, 11.

BEYOND THE CORRELATIONS

Shell-side flow maldistribution, tube vibration, tubesheet and nozzle stresses, thermal fatigue — we model exchangers with CFD and FEA.

Submit a Problem →

More calculators