D35 vs D80

D80 is about twice as stiff as D35. It is 1.7 times as dense. Per unit mass D80 is 1.2 times as stiff. Strength: f_m,k = 35 MPa for D35, f_m,k = 80 MPa for D80.

Side by side

ratio = D80 / D35 · log scale
Property D35 D80UnitRatio¼×1×4×
E₁ Modulus, direction 1 12 24 GPa 2×
E₂ Modulus, direction 2 0.8 1.6 GPa 2×
E₃ Modulus, direction 3 0.8 1.6 GPa 2×
G₁₂ Shear modulus 1-2 0.75 1.5 GPa 2×
G₁₃ Shear modulus 1-3 0.75 1.5 GPa 2×
E₀,₀₅ Modulus parallel to grain, 5 % fractile 10.1 20.2 GPa 2×
ρ Density 650 1080 kg/m³ 1.66×
ρ_k Density, characteristic (5 % fractile) 540 900 kg/m³ 1.67×
f_m,k Bending strength 35 80 MPa 2.29×
f_t,0,k Tension parallel to grain 21 48 MPa 2.29×
f_t,90,k Tension perpendicular to grain 0.6 0.6 MPa 1×
f_c,0,k Compression parallel to grain 25 38 MPa 1.52×
f_c,90,k Compression perpendicular to grain 5.4 13.5 MPa 2.5×
f_v,k Shear strength 4.1 5 MPa 1.22×
E/ρ Specific stiffness E/ρ · derived 18.46 22.22 MJ/kg 1.2×
c₀ Bar wave speed √(E/ρ) · derived 4297 4714 m/s 1.1×
f/ρ Specific strength f/ρ · derived 53.85 74.07 kJ/kg 1.38×

Values at the first thickness band or product form of each material (EN 338:2016; EN 338:2016). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.