D24 vs D35

D35 is 1.2 times as stiff as D24. It is 1.1 times as dense. Per unit mass D35 is 1.1 times as stiff. Strength: f_m,k = 24 MPa for D24, f_m,k = 35 MPa for D35.

Side by side

ratio = D35 / D24 · log scale
Property D24 D35UnitRatio¼×1×4×
E₁ Modulus, direction 1 10 12 GPa 1.2×
E₂ Modulus, direction 2 0.67 0.8 GPa 1.19×
E₃ Modulus, direction 3 0.67 0.8 GPa 1.19×
G₁₂ Shear modulus 1-2 0.63 0.75 GPa 1.19×
G₁₃ Shear modulus 1-3 0.63 0.75 GPa 1.19×
E₀,₀₅ Modulus parallel to grain, 5 % fractile 8.4 10.1 GPa 1.2×
ρ Density 580 650 kg/m³ 1.12×
ρ_k Density, characteristic (5 % fractile) 485 540 kg/m³ 1.11×
f_m,k Bending strength 24 35 MPa 1.46×
f_t,0,k Tension parallel to grain 14 21 MPa 1.5×
f_t,90,k Tension perpendicular to grain 0.6 0.6 MPa 1×
f_c,0,k Compression parallel to grain 21 25 MPa 1.19×
f_c,90,k Compression perpendicular to grain 4.9 5.4 MPa 1.1×
f_v,k Shear strength 3.7 4.1 MPa 1.11×
E/ρ Specific stiffness E/ρ · derived 17.24 18.46 MJ/kg 1.07×
c₀ Bar wave speed √(E/ρ) · derived 4152 4297 m/s 1.03×
f/ρ Specific strength f/ρ · derived 41.38 53.85 kJ/kg 1.3×

Values at the first thickness band or product form of each material (EN 338:2016; EN 338:2016). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.