D35 vs D70

D70 is 1.7 times as stiff as D35. It is 1.5 times as dense. Per unit mass D70 is 1.1 times as stiff. Strength: f_m,k = 35 MPa for D35, f_m,k = 70 MPa for D70.

Side by side

ratio = D70 / D35 · log scale
Property D35 D70UnitRatio¼×1×4×
E₁ Modulus, direction 1 12 20 GPa 1.67×
E₂ Modulus, direction 2 0.8 1.33 GPa 1.66×
E₃ Modulus, direction 3 0.8 1.33 GPa 1.66×
G₁₂ Shear modulus 1-2 0.75 1.25 GPa 1.67×
G₁₃ Shear modulus 1-3 0.75 1.25 GPa 1.67×
E₀,₀₅ Modulus parallel to grain, 5 % fractile 10.1 16.8 GPa 1.66×
ρ Density 650 960 kg/m³ 1.48×
ρ_k Density, characteristic (5 % fractile) 540 800 kg/m³ 1.48×
f_m,k Bending strength 35 70 MPa 2×
f_t,0,k Tension parallel to grain 21 42 MPa 2×
f_t,90,k Tension perpendicular to grain 0.6 0.6 MPa 1×
f_c,0,k Compression parallel to grain 25 36 MPa 1.44×
f_c,90,k Compression perpendicular to grain 5.4 12 MPa 2.22×
f_v,k Shear strength 4.1 5 MPa 1.22×
E/ρ Specific stiffness E/ρ · derived 18.46 20.83 MJ/kg 1.13×
c₀ Bar wave speed √(E/ρ) · derived 4297 4564 m/s 1.06×
f/ρ Specific strength f/ρ · derived 53.85 72.92 kJ/kg 1.35×

Values at the first thickness band or product form of each material (EN 338:2016; EN 338:2016). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.