D24 vs D55

D55 is 1.6 times as stiff as D24. It is 1.4 times as dense. Per unit mass D55 is 1.1 times as stiff. Strength: f_m,k = 24 MPa for D24, f_m,k = 55 MPa for D55.

Side by side

ratio = D55 / D24 · log scale
Property D24 D55UnitRatio¼×1×4×
E₁ Modulus, direction 1 10 15.5 GPa 1.55×
E₂ Modulus, direction 2 0.67 1.03 GPa 1.54×
E₃ Modulus, direction 3 0.67 1.03 GPa 1.54×
G₁₂ Shear modulus 1-2 0.63 0.97 GPa 1.54×
G₁₃ Shear modulus 1-3 0.63 0.97 GPa 1.54×
E₀,₀₅ Modulus parallel to grain, 5 % fractile 8.4 13 GPa 1.55×
ρ Density 580 790 kg/m³ 1.36×
ρ_k Density, characteristic (5 % fractile) 485 660 kg/m³ 1.36×
f_m,k Bending strength 24 55 MPa 2.29×
f_t,0,k Tension parallel to grain 14 33 MPa 2.36×
f_t,90,k Tension perpendicular to grain 0.6 0.6 MPa 1×
f_c,0,k Compression parallel to grain 21 32 MPa 1.52×
f_c,90,k Compression perpendicular to grain 4.9 6.6 MPa 1.35×
f_v,k Shear strength 3.7 4.7 MPa 1.27×
E/ρ Specific stiffness E/ρ · derived 17.24 19.62 MJ/kg 1.14×
c₀ Bar wave speed √(E/ρ) · derived 4152 4429 m/s 1.07×
f/ρ Specific strength f/ρ · derived 41.38 69.62 kJ/kg 1.68×

Values at the first thickness band or product form of each material (EN 338:2016; EN 338:2016). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.