C22 vs C35

C35 is 1.3 times as stiff as C22. It is 1.1 times as dense. Per unit mass C35 is 1.1 times as stiff. Strength: f_m,k = 22 MPa for C22, f_m,k = 35 MPa for C35.

Side by side

ratio = C35 / C22 · log scale
Property C22 C35UnitRatio¼×1×4×
E₁ Modulus, direction 1 10 13 GPa 1.3×
E₂ Modulus, direction 2 0.33 0.43 GPa 1.3×
E₃ Modulus, direction 3 0.33 0.43 GPa 1.3×
G₁₂ Shear modulus 1-2 0.63 0.81 GPa 1.29×
G₁₃ Shear modulus 1-3 0.63 0.81 GPa 1.29×
E₀,₀₅ Modulus parallel to grain, 5 % fractile 6.7 8.7 GPa 1.3×
ρ Density 410 470 kg/m³ 1.15×
ρ_k Density, characteristic (5 % fractile) 340 390 kg/m³ 1.15×
f_m,k Bending strength 22 35 MPa 1.59×
f_t,0,k Tension parallel to grain 13 22.5 MPa 1.73×
f_t,90,k Tension perpendicular to grain 0.4 0.4 MPa 1×
f_c,0,k Compression parallel to grain 20 25 MPa 1.25×
f_c,90,k Compression perpendicular to grain 2.4 2.7 MPa 1.12×
f_v,k Shear strength 3.8 4 MPa 1.05×
E/ρ Specific stiffness E/ρ · derived 24.39 27.66 MJ/kg 1.13×
c₀ Bar wave speed √(E/ρ) · derived 4939 5259 m/s 1.06×
f/ρ Specific strength f/ρ · derived 53.66 74.47 kJ/kg 1.39×

Values at the first thickness band or product form of each material (EN 338:2016; EN 338:2016). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.