C35/45 vs C60/75

C60/75 is 1.1 times as stiff as C35/45. Their densities are about the same. Per unit mass C60/75 is 1.1 times as stiff. Strength: f_ck = 35 MPa for C35/45, f_ck = 60 MPa for C60/75.

Side by side

ratio = C60/75 / C35/45 · log scale
Property C35/45 C60/75UnitRatio¼×1×4×
E Young's modulus 34 39 GPa 1.15×
G Shear modulus 14.17 16.25 GPa 1.15×
ν Poisson's ratio 0.2 0.2 – 1×
ρ Density 2447 2447 kg/m³ 1×
γ Weight density 24 24 kN/m³ 1×
α Coefficient of thermal expansion 10 10 10⁻⁶/K 1×
f_ck Characteristic cylinder strength 35 60 MPa 1.71×
f_ck,cube Characteristic cube strength 45 75 MPa 1.67×
f_cm Mean cylinder strength 43 68 MPa 1.58×
f_ctm Mean tensile strength 3.2 4.4 MPa 1.38×
f_ctk,0.05 Tensile strength, 5 % fractile 2.2 3.1 MPa 1.41×
f_ctk,0.95 Tensile strength, 95 % fractile 4.2 5.7 MPa 1.36×
ε_c1 Strain at peak stress 2.25 2.6 ‰ 1.16×
ε_cu1 Ultimate strain 3.5 3 ‰ 0.857×
ε_c2 Strain at peak, parabola–rectangle 2 2.3 ‰ 1.15×
ε_cu2 Ultimate strain, parabola–rectangle 3.5 2.9 ‰ 0.829×
n Exponent, parabola–rectangle 2 1.6 – 0.8×
ε_c3 Strain at peak, bilinear 1.75 1.9 ‰ 1.09×
ε_cu3 Ultimate strain, bilinear 3.5 2.9 ‰ 0.829×
E/ρ Specific stiffness E/ρ · derived 13.89 15.94 MJ/kg 1.15×
c₀ Bar wave speed √(E/ρ) · derived 3727 3992 m/s 1.07×
f/ρ Specific strength f/ρ · derived 14.3 24.52 kJ/kg 1.71×

Values at the first thickness band or product form of each material (EN 1992-1-1; EN 1992-1-1). A minimum and a characteristic value are not the same kind of number — read the ratio as a guide. Each material's page lists every band and every source.